How is the spray pattern of the Side Wall Type Sprinkler Head designed?

How is the spray pattern of the Side Wall Type Sprinkler Head designed?

The spray pattern of the Side wall type sprinkler head is tailored to the characteristics of the building and the type of fire, aiming to extinguish the fire efficiently through precise water flow distribution. The design of the spray pattern mainly considers the following factors:

The spray pattern of the Side wall type sprinkler head usually adopts fan-shaped spraying, that is, the water flow spreads out from the nozzle in a fan shape to cover a large area. This spray pattern can disperse water around the fire source in a short time, ensuring that the entire fire area can be covered and the spread of flames can be suppressed.

The spray angle of the Side wall type sprinkler head is usually set between **90° and 120°**. This angle design allows the water flow to cover a large space around the wall, which is particularly suitable for large-area fire control. The choice of spray angle is optimized according to the structure of the building to ensure that it can effectively respond to fires of different sizes in various environments.

The Side wall type sprinkler head adopts Mist Spray Technology, which is designed to spray water into fine water mist particles at high pressure. This fine mist of water flow not only has a strong cooling effect, but also effectively reduces the smoke and toxic gases produced by the fire, reducing the secondary damage caused by the fire.

Some high-end Side wall type sprinkler heads also use technology to automatically adjust the spraying intensity. In the early stage of a fire, the system automatically adjusts the spraying intensity of the water flow according to the size of the fire source and temperature changes. This design can ensure efficient fire extinguishing in the early stage of a fire, and avoid excessive waste of water flow after the fire is under control, thereby achieving the dual goals of energy saving and efficient fire extinguishing.

The spraying pattern of the Side wall type sprinkler head adopts a scientific water flow distribution design to ensure that every drop of water can effectively cover the fire source area. This design ensures that the water flow evenly covers the fire area through the optimization of the multi-hole nozzle and the internal water flow distribution system, avoiding the problem of insufficient or excessive water flow in some areas of traditional sprinklers.

Optimized design of the spraying pattern of the Side wall type sprinkler head
The spraying pattern of the Side wall type sprinkler head is not only suitable for extinguishing ordinary fires, but also optimized to achieve the effect in different fire scenarios. For example, in warehouses, industrial areas and other environments where fire sources are concentrated and there may be a large amount of flammable materials, the Side wall type sprinkler head can effectively reduce the spread of fire through strong water flow coverage and precise spraying angles.

Compared with traditional ceiling sprinklers, the Side wall type sprinkler head can more accurately control the direction and distribution of water flow. The design of the spray pattern makes the water flow mainly concentrated near the fire source, avoiding the traditional sprinkler head often dispersing the water flow to unnecessary areas. Especially in some places with small spaces or many equipment, the precise control of water flow can not only save water, but also reduce potential damage to other areas.

In some modern buildings, the Side wall type sprinkler head is equipped with an intelligent control system that can adjust the spray pattern in real time according to the type and development stage of the fire. For example, in the early stage of a fire, the intelligent system can quickly adjust the spray intensity and coverage according to temperature changes to ensure the efficient operation of the fire extinguishing system.

Due to the uniqueness and efficiency of its spray pattern, Side wall type sprinkler head has been widely used in many specific environments, especially in places with limited space or complex structures:

High-rise buildings: In high-rise buildings, due to the large ceiling height, traditional ceiling sprinklers may not be able to effectively cover the entire area, while Side wall type sprinkler head can cover a larger area through precise spraying angles to ensure fire extinguishing effect.

Warehouse and industrial environments: In warehouses and industrial areas, especially where items are piled high or densely, Side wall type sprinkler head can quickly cover the fire source through fan-shaped spray patterns to suppress the spread of fire.

Art galleries and museums: In these places with special requirements for fire, Side wall type sprinkler head avoids direct impact of water flow on valuables through fine mist spraying technology, and can handle fire more gently